News | February 20, 2015

Cardiology 2015 Conference Focuses on Children’s Heart Disease

Research topics included brain injury, radiation exposure

February 20, 2015 — Pediatric cardiology researchers and clinicians from numerous centers around the world gathered at the Cardiology 2015: the 18th Annual Update on Pediatric and Congenital Cardiovascular Disease conference, Feb. 11-15 in Scottsdale, Ariz. sponsored by The Children’s Hospital of Philadelphia and Phoenix Children’s Hospital. Among the many scientists who presented research at the event, the conference organizers chose eight clinical researchers as finalists for the Outstanding Investigator Award. The following news briefs summarize their presentations of research in congenital heart disease (CHD):

Risk of White-Matter Injury Before Infant Cardiac Surgery Linked to Oxygen Flow in Brain
Recent research in infants with critical CHD has shown that a longer period between birth and surgery increases the risk of injury to the brain's white matter, a condition called periventricular leukomalacia (PVL). This study of 35 neonates with critical CHD at The Children's Hospital of Philadelphia analyzed cerebral physiology during the vulnerable preoperative period. The newborns had two-ventricle anatomy or single-ventricle anatomy, with or without arch obstruction. In all groups, cerebral tissue oxygen saturation decreased from time-of-birth until surgery. The findings suggest that the increased risk for PVL stems from oxygen demand and a natural increase in cerebral oxygen metabolism not being met by oxygen delivery. Therapeutic strategies to shorten the time to surgery, or to increase cerebral oxygen delivery or decrease cerebral oxygen demand, could mitigate the risk for PVL.


Jennifer M. Lynch, Ph.D., et al, The Children’s Hospital of Philadelphia and the University of Pennsylvania; Pre-operative Cerebral Hemodynamics from Birth Until Surgery in Infants with Critical Congenital Heart Disease [abstract 1007, Thurs., Feb. 12.]

Practice Changes Reduce Radiation Exposure in Pediatric Cardiac Cath Procedures
This study analyzed practice changes in the pediatric cardiac catheterization laboratory at Children’s Mercy Hospital, aimed at reducing patient and provider exposure to ionizing radiation. After a 30-day trial and education period, the center implemented changes in technical and clinical practice such as weight-based reductions in preset fluoroscopy and angiography frame rates, more consistent use of collimators and shields, and increased use of stored fluoroscopy and virtual magnification. This quality improvement study analyzed all 353 cardiac catheterization procedures, 6 months before and 8 months after instituting the changes. The mean cumulative skin dose per minute of radiation decreased significantly, from 91.30 (plus or minus 166.23) cGy-cm2/min. to 58.42 (plus or minus 98.79) cGy-cm2/min. There were significant reductions across all age and weight subgroups. In addition, radiation exposure to physicians decreased by 46 percent from 2011 to 2012.


Nichole Gubbins, M.D., et al, Children’s Mercy Hospital, University of Missouri-Kansas City; Radiation Dose Reduction in the Pediatric Interventional Cardiovascular Laboratory: A Quality Improvement Study [abstract 878, Thurs., Feb. 12.]

For more information: www.chop.edu


Related Content

News | Angiography

Oct. 7, 2024 — The Society for Cardiovascular Angiography & Interventions (SCAI) recently announced the publication of ...

Home October 07, 2024
Home
News | Angiography

January 31, 2024 — Coronary artery calcification is increasing in prevalence, leading to greater risks both during ...

Home January 31, 2024
Home
Feature | Angiography | By Bhvita Jani

The world market for interventional X-ray and mobile C-arm equipment is forecast to reach over $4.9 billion by 2026 ...

Home November 09, 2022
Home
News | Angiography
April 6, 2022 – According to ARRS’ American Journal of Roentgenology (AJR), the 3-T Dixon gradient-recalled echo (GRE) ...
Home April 06, 2022
Home
News | Angiography

April 7, 2021 — Philips Healthcare announced U.S. Food and Drug Administration (FDA) 510(k) clearance for its Philips ...

Home April 07, 2021
Home
Feature | Angiography | By Bhvita Jani

January 19, 2021 – With the postponement of non-essential elective surgeries and medical procedures in 2020 to conserve ...

Home January 19, 2021
Home
News | Angiography

December 3, 2020 — GE Healthcare is introducing a new version of its robotic driven angiography system for image guided ...

Home December 01, 2020
Home
Feature | Angiography | Dave Fornell, Editor

Philips is working on a prototype cath lab angiographic imaging system that might be able to replace the current X-ray ...

Home March 12, 2020
Home
News | Angiography

February 12, 2020 — The University of Wisconsin (UW) Health’s University Hospital in Madison, Wis., recently became the ...

Home February 12, 2020
Home
News | Angiography

October 9, 2019 — In the complex and fast-paced world of healthcare, customers face the challenge of staying up-to-date ...

Home October 09, 2019
Home
Subscribe Now