June 29, 2022 — A spiral wave of electrical activity in the heart can cause catastrophic consequences. One spiral wave creates tachycardia — a heart rate that’s too fast — and multiple spirals cause a state of disorganized contraction known as fibrillation. Researchers from the Georgia Institute of Technology offer a new method to disrupt spiral waves that uses less energy and that may be less painful than traditional defibrillation. 

This research has been ongoing in School of Physics Professor Flavio Fenton’s lab with his student Noah DeTal and research scientist Abouzar Kaboudian. Their latest findings are published in the paper, “Terminating Spiral Waves with a Single Designed Stimulus: Teleportation as the Mechanism for Defibrillation,” in the journal Proceedings of the National Academy of Science

The Problem with Spiral Waves 

Electrical waves enable the heart to contract and send blood throughout the body. When a wave becomes a spiral, its rotation is faster than the heart’s natural pacemaker and suppresses normal cardiac function. Instead, one spiral wave can spawn more spirals until the heart is overtaken by multiple spiral waves, leading to disorganized contraction, and preventing the heart from supplying the body with blood. 

For years, scientists and doctors have worked to find the best way to stop spiral waves before they get out of control. Yet for over half a century the best method has been a single strong electric shock. The 300 joules of energy required for defibrillation excites not just the heart cells, but the entire body, making it very painful for the patient.  

Over the years researchers have experimented with using weaker shocks to reorganize arrhythmias.  

“We still did not have a clear understanding of how defibrillation worked,” said Fenton. “This research explains the minimum energy required to actually terminate an arrhythmia and I believe it clarifies the mechanism for defibrillation.” 

The Symmetrical Solution 

The researchers determined that because spiral waves develop in pairs, they must also be terminated in pairs. Every spiral wave is connected to another spiral going in the opposite direction. Bringing the spiral waves together through an electric shock instantly eliminates both waves. 

The researchers used a mathematical method to identify the key regions for electrical shock stimulation to target spiral waves. They determined that a stimulus delivered to the tissue areas a spiral wave just left and were able sustain a new wave could defibrillate the heart.   

In the process of terminating the spiral waves, the researchers were actually moving them, as well, through a concept they named “teleportation.” 

“We call it teleportation because it’s very similar to what you see in science fiction where something is moved instantaneously from one place to another,” Fenton said. 

Spiral waves can be teleported anywhere in the heart using this approach. In particular, spiral waves can be moved so that they collide with their partners, which extinguishes them. Fenton explained that for successful defibrillation to occur, all pairs of spiral waves must be eliminated in this manner. 

The researchers plan to further test this concept using two-dimensional cultures of heart cells. 

“The next step is to is to prove experimentally that what we did numerically is possible,” Fenton said. 

Eventually, Fenton added, they want to develop methods that could be used clinically, and are partnering with cardiologists at Emory University on this work. 

CITATION: Noah DeTal, Abouzar Kaboudian, Flavio Fenton; Terminating Spiral Waves with a Single Designed Stimulus: Teleportation as the Mechanism for Defibrillation. PNAS, 119 (24). 

For more information: www.gatech.edu 


Related Content

News | Cardiac Imaging

Pfizer has awarded $80,000 to Rutgers Robert Wood Johnson Medical School (RWJMS) to fund an Amyloidosis Fellowship at ...

Home December 19, 2024
Home
News | Cardiac Imaging

Dec. 11, 2024 — Genetesis, Inc. has launched the CardioFlux Membership program. CardioFlux Membership is designed to be ...

Home December 18, 2024
Home
News | Cardiac Imaging

Nov. 13, 2024 – A recent study has demonstrated the value of the single-exposure dual-energy X-ray detector in advancing ...

Home November 13, 2024
Home
News | Cardiac Imaging

Oct. 15, 2024 — Four of the seven Medicare Administrative Contractors (MACs) have released final local coverage ...

Home October 16, 2024
Home
News | Cardiac Imaging

Oct. 15, 2024 – Elucid has announced that four of the seven Medicare Administrative Contractors (MACs) will extend ...

Home October 15, 2024
Home
News | Cardiac Imaging

PHOTO CAPTION: The Elucid PlaqueIQ user interface is a fully interactive visualization of the patient’s coronary anatomy ...

Home October 01, 2024
Home
News | Cardiac Imaging

Aug. 21, 2024 — NANO-X IMAGING LTD recently announced that its deep-learning medical imaging analytics subsidiary, Nanox ...

Home August 22, 2024
Home
News | Cardiac Imaging

July 23, 2024 — EMVision, an Australian medical device company focused on the development and commercialization of ...

Home July 23, 2024
Home
News | Cardiac Imaging

July 12, 2024 — Researchers have developed a groundbreaking method for analyzing heart MRI scans with the help of ...

Home July 12, 2024
Home
News | Cardiac Imaging

June 10, 2024 — New expert consensus from the Society of Cardiovascular Computed Tomography (SCCT) reviews previously ...

Home June 10, 2024
Home
Subscribe Now