Feature | July 23, 2013 | Dave Fornell

Not Everyone is on the Same Page to Lower Radiation Dose

Finding ways to lower patient radiation dose from both medical imaging and interventional cardiology has become a major trend. However, when vendors start talking dose, it is important to realize there are no set industry standards agreed upon by manufacturers to calculate dose. For this reason, I call into question vendors’ statistics of how much their technology can lower dose by up to 20, 50 or even 80 percent.  While new technologies such as iterative reconstruction, more sensitive detectors and ECG gating do indeed lower dose, quantifying it can be a moving target. 

DAIC created a comparison chart for technologies to help lower computed tomography (CT) dose (see Page 34).  Vendors were asked, “How does your system calculate estimated dose?” As an example, we asked what they use as a conversion factor to calculate dose in MilliSieverts (mSv) based on dose-length product (DLP) or CT dose index volume (CTDlvol) found on a scan’s DICOM header.  To our surprise, this central question of how vendors arrive at their dose statistics was not answered by anyone. I wrote back posing this question again and only received responses from GE and Philips — the rest declined to comment.  The bottom line is that there are no industry standards agreed upon by manufacturers. 

“There have been publications to estimate effective dose from DLP or CTDI through conversion factors and there are organ dose simulations you can calculate using Monte Carlo techniques, however each method has its own level of uncertainty,” said Leslie Lakis, Philips senior public relations manager, imaging systems. “Therefore, physicists are left to use whatever effective dose conversion they prefer until the scientific community formally adopts a standard method for effective dose conversion.”

Ken Denison, global marketing director, CT, global MICT dose leader, GE Healthcare, said each manufacturer takes measurements on 16 and 32 cm water phantoms for a range of parameters (kVp, mA, slice thickness, pitch, etc.) and this allows them to then estimate the exposure using CTDIvol. However, he said GE does not provide an estimate for whole-body effective dose on its systems. “This is because there are different k-factors that may be used to convert DLP to and estimate of whole-body effective dose. Different users may choose which factors to use differently,” he said. 

Due to the variability cited, I often wonder if true apples-to-apples comparisons between vendors’ technologies are possible. Also, as more states consider laws requiring providers to record patient dose, what measure is being used?  It must be realized that all dose calculations are based on 16 and 32 cm phantoms, which are are not real people and most patients are 16 or 32 cm across. In addition, each patient body habitus impacts the individual level of dose, so all dose measures are really a best guess, not an exact science.


Related Content

News | Computed Tomography (CT)

July 16, 2024 — Arineta, a leader in advancing cardiovascular imaging solutions through cutting-edge technology, proudly ...

Home July 16, 2024
Home
News | Computed Tomography (CT)

May 1, 2024 —In this 3-stage study, 3 cohorts were used for diagnostic performance, and prognostic performance ...

Home May 01, 2024
Home
News | Computed Tomography (CT)

April 22, 2024 — A new study showed that a non-invasive imaging test can help identify patients with coronary artery ...

Home April 22, 2024
Home
Feature | Computed Tomography (CT) | By Alberto Morales, MD

Cardiac CT scans, recommended by the American College of Cardiology (ACC) and the American Heart Association (AHA) as ...

Home March 20, 2024
Home
News | Computed Tomography (CT)

February 20, 2024 — Ultrahigh-spatial-resolution photon-counting detector CT improved assessment of coronary artery ...

Home February 20, 2024
Home
News | Computed Tomography (CT)

HeartFlow is offering a free webinar based on a recent study that measured the ability of the of its roadmap analysis to ...

Home January 15, 2024
Home
News | Computed Tomography (CT)

December 19, 2023 — Siemens Healthineers announced the Food and Drug Administration (FDA) clearance of the Somatom Pro ...

Home December 19, 2023
Home
Feature | Computed Tomography (CT) | By Andrew Michalski, PhD and Rohit Sood MD, PhD

Coronary artery disease (CAD), also known as ischemic heart disease, is the most common heart disease with a prevalence ...

Home December 05, 2023
Home
News | Computed Tomography (CT)

October 26, 2023 — HeartFlow, Inc., a leader in non-invasive integrated artificial intelligence (AI) heart care ...

Home October 26, 2023
Home
News | Computed Tomography (CT)

October 13, 2023 — Arineta Cardiac Imaging is excited to announce the FDA 510(k) clearance of the SpotLight and ...

Home October 13, 2023
Home
Subscribe Now