Technology | Drug-Eluting Balloons | July 18, 2016

Medtronic Receives FDA Approval for In.Pact Admiral DCB 150 mm Lengths

Approval creates expanded treatment options for patients with longer superficial femoral artery lesions

Medtronic, In.Pact Admiral drug coated balloon, DCB, FDA approval, 150 mm length

July 18, 2016 — Medtronic plc has received U.S. Food and Drug Administration (FDA) approval for the IN.PACT Admiral drug-coated balloon (DCB) in longer, 150 mm lengths. The new 150 mm-length balloon — available in 4, 5 and 6 mm diameters — will provide greater treatment options for long lesions in patients with peripheral artery disease (PAD).

"The long lesion (10-18 cm) sub-group outcomes from the IN.PACT SFA Trial at one year demonstrated superiority over balloon angioplasty," said John Laird, M.D., interventional cardiologist at University of California Davis Medical Center and co-principal investigator for the IN.PACT SFA Trial. "The availability of the 150 mm length sizes will expand proven treatment options to more patients."

The IN.PACT SFA Trial, a prospective, multi-center, randomized, controlled pivotal trial demonstrated, in a subgroup of patients with lesions >=10 cm and <18 cm, a clinically-driven target lesion revascularization (CD-TLR) rate of 5.3 percent for the IN.PACT Admiral DCB arm (n=79) and 32.4 percent for the PTA arm (n=36) (p<0.001). There were no device or procedure-related deaths, no occurrences of major target limb amputation, and a 3.9 percent thrombosis rate in the IN.PACT Admiral DCB arm versus 5.9 percent in the PTA arm through 12 months (p=0.326) in this subgroup.

The IN.PACT Admiral drug-coated balloon is a primary endovascular therapy that enables physicians to treat claudication and restenosis for patients with superficial femoral artery (SFA) disease. The DCB's primary mode of action is physical dilatation of the vessel lumen by percutaneous transluminal angioplasty (PTA), and the proven paclitaxel drug is intended to prevent artery narrowing by minimizing scar tissue formation.

The device received CE Mark in 2009 to treat PAD and was approved by the FDA in December 2014 to treat superficial femoral and popliteal arteries.

For more information: www.medtronic.com


Related Content

News | Balloon Catheter

June 13, 2024 — The U.S. Food and Drug Administration (FDA) announced that Teleflex, and their subsidiary Arrow ...

Home June 13, 2024
Home
News | Balloon Catheter

April 4, 2024 — The U.S. Food and Drug Administration (FDA) announced that Medos International Sàrl is recalling ...

Home April 04, 2024
Home
News | Balloon Catheter

January 18, 2024 — Summa Therapeutics, LLC announced that the first-in-man injectable angioplasty procedures for ...

Home January 18, 2024
Home
News | Balloon Catheter
Cardiovascular Systems, Inc., a medical device company developing and commercializing innovative interventional ...
Home February 25, 2022
Home
News | Balloon Catheter

February 15, 2022 – CERENOVUS, an emerging leader in neurovascular care and part of Johnson & Johnson Medical Devices ...

Home February 15, 2022
Home
News | Balloon Catheter

May 20, 2021 — Boston Scientific Corporation announced it has initiated the AGENT IDE trial for the Agent Drug-Coated ...

Home May 20, 2021
Home
Feature | Balloon Catheter | By Dave Fornell, Editor

The first devices developed for interventional cardiology were percutaneous transluminal coronary angioplasty (PTCA) ...

Home March 16, 2021
Home
Feature | Balloon Catheter

February 17, 2021 — The U.S. Food and Drug Administration (FDA) has cleared Shockwave Medical's Intravascular ...

Home February 17, 2021
Home
News | Balloon Catheter

June 4, 2020 — Transit Scientific announced the U.S. Food and Drug Administration (FDA) cleared the XO Score ...

Home June 04, 2020
Home
News | Balloon Catheter

February 24, 2020 — Abbott has voluntarily recalled specific lots of two types of its coronary angioplasty catheters — ...

Home February 24, 2020
Home
Subscribe Now