Feature | November 01, 2013

Clinical Trial Finds CoreValve Reduces Rate of Death, Stroke in Patients With Aortic Stenosis

Results of the CoreValve Extreme Risk trial presented at TCT 2013

heart valve repair hybrid or cath lab structural heart tct medtronic corevalve

November 1, 2013 — In a clinical trial, the Medtronic Corevalve self-expanding transcatheter aortic valve met the key performance objective of reducing death and stroke in patients with severe aortic stenosis at “extreme risk” for surgery. Results of the CoreValve Extreme Risk trial were presented at the 25th annual Transcatheter Cardiovascular Therapeutics scientific symposium (TCT 2013) in San Francisco.
 
The CoreValve Extreme Risk trial was a prospective, multicenter, controlled, non-randomized, single-arm investigation evaluating the safety and efficacy of the transfemorally implanted CoreValve self-expanding transcatheter heart valve. The trial was conducted in 487 patients with symptomatic, severe aortic stenosis. 
 
All patients were deemed to be at extreme risk for surgical aortic valve replacement, and were thus treated with the Corevalve device. The primary endpoint was a composite of all-cause mortality or major stroke rate at 12 months; the Kaplan-Meier determined event rate was compared with a pre-specified objective performance goal (OPG). 
 
Of the 487 patients enrolled in the study, 471 had an attempted implantation and were designated as the primary "as treated" analysis population. Patients were elderly (83.1 years), and were severely symptomatic (NYHA class III or IV, 91.9 percent). The Society for Thoracic Surgery predicted risk of mortality was 10.3 percent ± 5.6 percent and was > 15 percent in 17.6 percent of patients. 
 
At 12 months, the composite rate of death or major stroke was 25.5 percent, significantly below the 95 percent confidence interval of the performance goal, which was set at 43 percent. While moderate paravalvular leak was observed in 11 percent of patients at one month, 80 percent of patients with moderate paravalvular (PV) leak at one month who survived to one year experienced a reduction in PV leak over time.
 
“The CoreValve Extreme Risk study achieved its primary endpoint of a reduction in all cause mortality or major stroke at one year compared to a rigorously defined OPG,” said Jeffrey Popma, M.D., lead investigator, director, Interventional Cardiology, Beth Israel Deaconess Medical Center.
 
Medtronic has three FDA IDE trials evaluating the Corevalve for high-risk and extreme-risk surgical patients and in patients at intermediate risk for open-heart aortic valve replacement (SURTAVI Trial).
 
For more information: www.crf.org, www.medtronic.com

Related Content

News | Heart Valve Technology

Sept. 1, 2024 — Researchers at UTHealth Houston have identified genetic variants linked to a rare form of bicuspid ...

Home September 04, 2024
Home
News | Heart Valve Technology

June 27, 2024 — The sheer scale of undiagnosed heart valve disease in our aging population has been revealed for the ...

Home June 27, 2024
Home
News | Heart Valve Technology

June 21, 2024 — UC San Francisco interventional cardiologists and interventional echocardiographers recently performed ...

Home June 21, 2024
Home
News | Heart Valve Technology

June 10, 2024 — Atrium Health Sanger Heart & Vascular Institute has successfully completed the first commercial ...

Home June 10, 2024
Home
News | Heart Valve Technology

April 17, 2024 —CPR Therapeutics, Inc. (CPR-T), an early-stage medtech startup funded by the N.I.H and N.S.F to develop ...

Home April 17, 2024
Home
News | Heart Valve Technology

April 1, 2024 — Roughly 25,000 Americans die each year from valvular heart disease, but researchers from Rutgers Health ...

Home April 01, 2024
Home
News | Heart Valve Technology

January 4, 2024 — Findings from a published case series research letter by the Henry Ford Health Structural Heart ...

Home January 04, 2024
Home
News | Heart Valve Technology

December 22, 2023 — TRiCares SAS (“TRiCares”), a privately held pioneer in the field of minimally invasive treatment of ...

Home December 22, 2023
Home
News | Heart Valve Technology

December 18, 2023 — Death rates related to infective endocarditis declined in most adults across the U.S. within the ...

Home December 18, 2023
Home
News | Heart Valve Technology

December 12, 2023 — Patients who received the anticoagulant drug warfarin after bioprosthetic aortic valve replacement ...

Home December 12, 2023
Home
Subscribe Now