Feature | June 04, 2012

Seven Reasons Why to Use Automated Blood Pressure Measurement for Cardiac Stress Testing

The SunTech Medical Tango+ Stress BP monitor collects accurate readings while a patient is moving.


Cardiac stress testing helps physicians diagnose various heart conditions and has become a vital diagnostic tool for all cardiac care facilities.[1]  A modern cardiac stress lab uses a digital electrocardiogram (ECG) stress system, sophisticated echocardiogram imaging, an electronically controlled treadmill/ergometer, and usually a manual cuff and bulb sphygmomanometer. If everything else in the lab is automated and state-of-the art, one might wonder why a blood pressure measurement tool from the 19th century is so prevalent in 21st century stress labs.

While there are plenty of automated blood pressure (BP) monitors designed to be used for clinical applications, most of these devices will not work in cardiac stress test applications. Only motion-tolerant blood pressure monitors designed specifically for handling the high noise, high motion environment of a stress lab can accurately and reliably collect BP measurements. Ideally, the BP monitor should distinguish Korotkoff sounds (K-sounds) from the large amount of background noise generated during a stress test.

There are several factors to consider about automated verses manual blood pressure monitoring:

Patient Safety

Patient safety is always the No. 1 priority when performing any type of medical testing. Automated blood pressure devices allow supervising clinicians to focus on the patient’s safety during a cardiac stress test instead of being distracted by taking manual blood pressure measurements. Automated stress BP monitors also allow all eyes to focus on the patient’s ECG for heartbeat irregularities, and the level of patient fatigue through body language.

 

Difficulty Hearing K-Sounds

Taking BP measurements with cuff, bulb and stethoscope can be difficult in a noisy environment. Foot strikes, cuff/arm movement and treadmill noise present during stress testing make it very difficult for even a trained ear to distinguish the nuances between various types of K-sounds. As a result, inaccurate readings are possible.[2]

 

Excessive Arm Movement During Testing

During a cardiac stress test, the patient is typically walking or running. Associated arm and body movement make it difficult to hold the patient’s arm still while taking a manual blood pressure measurement — which can further distract from accurate observation. With automated stress BP monitors, there is no need to hold the arm still since they are specifically designed to take accurate BP measurements on a moving arm.

 

Accuracy of BP Measurements During Stage Progression

During a Bruce protocol[3] (a commonly used diagnostic test used to evaluate cardiac function), an accurate manual BP reading at stage 4 and beyond really becomes a guess. While the goal is to reach a patient’s maximum heart rate, this will occur at different times for each person based on age, gender and physical condition. The formulas to calculate the patient’s target maximum heart rate are (male maximum heart rate = 220 – patient’s age; female maximum heart rate = 206 – [0.88 x patient’s age]).  In order to achieve the maximum heart rate the average patient will need to progress through several Bruce protocol stages.

A patient is usually jogging or running by stage 4, meaning there is a lot of patient movement associated with this stage and any later stage in the protocol.  This makes it even harder to hold the patient’s arm steady in order to perform a manual BP measurement. In addition, the motor noise of the treadmill increases as speed increases, as do the volume and intensity of the patient’s foot strikes. An automated stress BP monitor reduces these physical limitations through specific algorithms that allow the monitor to “see through” the motion and noise artifact, thereby producing a more accurate BP reading.

 

Reduction in Transcription Errors

An automated stress BP monitor can usually be integrated with the stress system to transmit readings automatically for recording in test reports, which can reduce manual transcription errors. It is also one less action required for clinicians.

 

Reliable Timing and Accuracy of BP Measurements

During stress testing, reliability and accuracy go hand-in-hand. Recording an accurate and reliable BP measurement at the correct intervals during a test can be difficult and stressful for clinicians and lab technicians. An automated stress BP monitor can be programmed to take an accurate reading at the proper time. An example of an executed timed interval would be to use the Bruce protocol stages. In general, measurements need to be taken at the two-minute mark during each of the three-minute timed stages.[5. 6] Automated devices will initiate readings at the precise moment during each stage, increasing reliability of the measurements.

 

One-Time Cuff Placement

For manual BP measurements, a stress technician is often applying and removing the cuff as needed.

Using the Bruce protocol again as an example, each stage lasts three minutes, and a proper manual BP measurement takes about 53 seconds (at 180 mmHg maximum inflation with American Heart Association-recommended[4] 2-3 mmHg/sec. deflation rate), the window of time to properly apply the cuff so that the artery marker is directly over the brachial artery is small. This increases the likelihood of improper cuff placement each time the cuff is applied. There is also an increased risk of infection transfer every time the clinician places and removes the cuff from the patient’s arm.[7] For automated BP measurements, the cuff should be able to remain on the patient through the duration of the stress test. This eliminates the hassle of re-applying the cuff for each Bruce protocol stage, helps ensure proper cuff placement and reduces the risk of spreading hospital acquired infections (HAI).

Cardiac stress testing has proven to be an effective method in the diagnosis of heart disease, cardiac function and ischemia. However, the excessive noise and motion associated with these tests make it hard to obtain an accurate BP measurement with a traditional cuff-and-bulb sphygmomanometer. Automatic blood pressure monitors designed specifically for handling the rigors of stress testing help remove subjectivity by increasing the accuracy and reliability of each measurement and automatically record the BP in the stress test system.

 

Editor’s note: This story was submitted by SunTech Medical, which makes the Tango+ Stress BP monitor. The system uses proprietary, motion-tolerant BP algorithms to overcome the noise and motion during stress testing.

 

 

References:

1. “Exercise Stress Testing in the Emergency Room?” Diagnosisheart.com. Jan. 5, 2012. Accessed Jan. 6, 2012. www.diagnosisheart.com/category/tests.

2. Cameron, James D., et al. “Accuracy of Automated Ausculated Blood Pressure Measurement During Supine Exercise and Treadmill Stress Electrocardiogram-testing.” Blood Pressure Monitoring 9.5 (2004): 269-275. 

3. “The Bruce Protocol.” Washington.edu. N.p., May 3, 2012. Accessed June 11, 2012, www.washington.edu/research/pathbreakers/1963a.html.

4. Smith, Liz. “New AHA Recommendations for Blood Pressure Measurement.” American Academy of Family Physicians 72.7 (2005): 1391-1398. Accessed May 11, 2012, www.aafp.org/afp/2005/1001/p1391.html>.

5. Laukkanen, Jari A., et al. “Systolic Blood Pressure During Recovery from Exercise and the Risk of Acute Myocardial Infarction in Middle-Aged Men.” Hypertension: Journal of the American Heart Association 44(2004):820-825. Accessed June 11, 2012.

6. Kurl, S, and et al. “Systolic Blood Pressure Response to Exercise Stress Test and Risk of Stroke.” Hypertension: Journal of the American Heart Association 32(2001):2036-2041. Accessed June, 11 2012.

7. “ClinicaClinical Research Supporting the Use of Disposable Blood Pressure Cuffs to Reduce the Spread of Healthcare Associated Infections.” SunTech Medical Inc, Dec. 14, 2012. Accessed June 11, 2012, www.suntechmed.com/downloads/Cuffs/white_papers/82-0109-00-MD_RevA.pdf.


Related Content

News | Blood Pressure Monitor

February 14, 2022 — Binah.ai, the leading provider of general health and wellness video-based monitoring solutions ...

Home February 14, 2022
Home
News | Blood Pressure Monitor

August 6, 2019 — Blood pressure monitoring might one day become as easy as taking a video selfie, according to new ...

Home August 06, 2019
Home
News | Blood Pressure Monitor

October 11, 2017 — The CT40 spot-check device from SunTech Medical has received third-party validation for blood ...

Home October 11, 2017
Home
Technology | Blood Pressure Monitor

January 17, 2017 — The new SunTech Oscar 2 24-hour ambulatory blood pressure monitoring system (ABPM) is now available ...

Home January 17, 2017
Home
Sponsored Content | Videos | Blood Pressure Monitor

SunTech demonstrated its new Tango M2 cardiac stress test automated blood pressure monitoring system at the American ...

Home March 26, 2013
Home
Subscribe Now