News | March 02, 2010

Software Upgrades Improve 320-Slice CT, Lowers Dose


March 2, 2010 – Cardiac enhancements to ensure the highest image quality at lower radiation doses are among the new software upgrades released this week for the Aquilion ONE CT system.

A new ONE Beat Prospective Reconstruction shortens the interval window and reduces radiation exposure time. This results in a radiation dose savings of 21 percent as the more efficient imaging lowers the radiation exposure to the patient.

Another upgrade, Real Time Beat Control, calculates the running real time average of the heart rate to predict the next heart beat for a more accurately timed scan. Important for patients with arrhythmias, this feature ensures better accuracy and improves image quality while reducing repetitive exams.

New optimized timing of SUREStart can accurately determine contrast uptake time for a more accurate image. The upgraded SUREStart makes the transition from bolus chase to cardiac scanning virtually seamless. This feature creates better contrast timing, improves image quality and lowers contrast dose.

The Aquilion ONE can image up to 16 cm of anatomy in one rotation using 320 ultra high-resolution 0.5 mm detector elements impacting the diagnosis of patients who present with chest pain. With the new wide volume cardiac protocol (works-in-progress) for the Aquilion ONE, clinicians can image the entire heart, lungs and aorta in just two rotations. This may help rule out cardiac and lung issues for patients with chest pain with high-quality images at low radiation doses. Using traditional 64-detector row CT systems, scanning this entire area could take up to 20 to 30 X-ray rotations. Designed for ECG-gated CT imaging, Toshiba’s new wide volume technology is allowing clinicians to image an even greater area in fewer rotations and far less radiation dose.

For more information: www.medical.toshiba.com


Related Content

News | Computed Tomography (CT)

July 16, 2024 — Arineta, a leader in advancing cardiovascular imaging solutions through cutting-edge technology, proudly ...

Home July 16, 2024
Home
News | Computed Tomography (CT)

May 1, 2024 —In this 3-stage study, 3 cohorts were used for diagnostic performance, and prognostic performance ...

Home May 01, 2024
Home
News | Computed Tomography (CT)

April 22, 2024 — A new study showed that a non-invasive imaging test can help identify patients with coronary artery ...

Home April 22, 2024
Home
Feature | Computed Tomography (CT) | By Alberto Morales, MD

Cardiac CT scans, recommended by the American College of Cardiology (ACC) and the American Heart Association (AHA) as ...

Home March 20, 2024
Home
News | Computed Tomography (CT)

February 20, 2024 — Ultrahigh-spatial-resolution photon-counting detector CT improved assessment of coronary artery ...

Home February 20, 2024
Home
News | Computed Tomography (CT)

HeartFlow is offering a free webinar based on a recent study that measured the ability of the of its roadmap analysis to ...

Home January 15, 2024
Home
News | Computed Tomography (CT)

December 19, 2023 — Siemens Healthineers announced the Food and Drug Administration (FDA) clearance of the Somatom Pro ...

Home December 19, 2023
Home
Feature | Computed Tomography (CT) | By Andrew Michalski, PhD and Rohit Sood MD, PhD

Coronary artery disease (CAD), also known as ischemic heart disease, is the most common heart disease with a prevalence ...

Home December 05, 2023
Home
News | Computed Tomography (CT)

October 26, 2023 — HeartFlow, Inc., a leader in non-invasive integrated artificial intelligence (AI) heart care ...

Home October 26, 2023
Home
News | Computed Tomography (CT)

October 13, 2023 — Arineta Cardiac Imaging is excited to announce the FDA 510(k) clearance of the SpotLight and ...

Home October 13, 2023
Home
Subscribe Now