Technology | August 06, 2008

XTENT Working to Bring Customizable Drug Eluting Stent Solution to CAD Patients


XTENT Inc.'s Custom NX stent system reportedly allows physicians to customize the length and diameter of the stent at the site of the lesion.
The system features a proprietary modular stent design that consists of multiple 6 mm cobalt chromium segments coated with Biolimus A9 and PLA, a biodegradable drug carrier. The Custom NX delivery system enables separation at each 6 mm segment and allows for the placement of up to 60 mm of stent. The Custom NX DES System has not been approved for sale by any regulatory authority.

Approximately 220 patients with coronary artery disease have been enrolled in three clinical trials of Custom NX, with up to two years of follow-up data available on some of those patients. The three trials, known as CUSTOM I, CUSTOM II and CUSTOM III, have typically enrolled challenging patient populations presenting with complex disease, including long, narrow and multiple lesions.

Earlier this year, XTENT announced positive six-month follow-up data from the CUSTOM III clinical trial, 90-patient prospective study to assess the safety and efficacy of the Custom NX DES system in CAD patients with up to two de novo lesions treatable with up to 60 mm of customizable stent length.

CUSTOM III enrolled a challenging patient population, with 67 percent of the lesions classified as complex B2/C, an average lesion length of 19.8 mm, and an average reference vessel diameter (RVD) of 2.6 mm. The CUSTOM III trial included some of the longest lesion lengths and smallest RVDs compared to previous drug eluting stent trials. Lesion length and RVD are two important indicators of disease complexity.

For the primary endpoint, MACE at 30 days, the rate was 2.2 percent, consisting of two in-hospital non Q-wave myocardial infarctions (MIs). At six-month follow-up the MACE rate for CUSTOM III was 7.8 percent. There were zero deaths, zero Q-wave MIs, two non Q-wave MIs, or 2.2 percent, and five clinically driven target lesion revascularizations, or 5.6 percent. There was one case of early stent thrombosis in the trial and zero late stent thrombosis. The in-stent late loss for CUSTOM III at six-month follow-up was 0.17 mm, the in-stent binary restenosis rate was 4.4 percent, and the neointimal hyperplasia (NIH) volume was 3.8 percent.

The Custom NX DES System has not been approved for sale by any regulatory authority.


Related Content

News | Stents Drug Eluting

July 2, 2024 — Biotronik announced the availability of an expanded Maximum Allowed Diameters (MAD) range for the Orsiro ...

Home July 02, 2024
Home
News | Stents Drug Eluting

October 31, 2023 — SMT (Sahajanand Medical Technologies), a leading medical device company in India, focused on ...

Home October 31, 2023
Home
News | Stents Drug Eluting

October 10, 2023 — Elixir Medical, a developer of innovative cardiovascular technologies, announced it will present ...

Home October 10, 2023
Home
News | Stents Drug Eluting

July 13, 2023 — Elixir Medical, a developer of breakthrough cardiovascular technologies, announced enrollment completion ...

Home July 13, 2023
Home
News | Stents Drug Eluting

July 12, 2023 — In a late breaking trial session during EuroPCR 2023 in Paris, on behalf of the HOST-IDEA study ...

Home July 12, 2023
Home
News | Stents Drug Eluting

May 25, 2023 — First-generation bioresorbable vascular scaffolds (BVS) may be just as effective as drug-eluting metallic ...

Home May 25, 2023
Home
News | Stents Drug Eluting

January 2, 2023 — The U.S. Food and Drug Administration (FDA) has approved the BioFreedom Drug Coated Coronary Stent ...

Home January 02, 2023
Home
News | Stents Drug Eluting

December 23, 2022 — According to Coherent Market Insights, the global Drug Eluting Stents market is estimated to be ...

Home December 23, 2022
Home
News | Stents Drug Eluting

June 2, 2022 — Elixir Medical, a developer of innovative, drug-eluting cardiovascular devices, announced print ...

Home June 02, 2022
Home
News | Stents Drug Eluting

February 16, 2022 – Elixir Medical, a developer of innovative, drug-eluting cardiovascular devices, has announced ...

Home February 16, 2022
Home
Subscribe Now